top of page
Flow

Human Physiology and Research

Digitimer has a long history of designing and manufacturing high output electronic stimulators and amplifiers that are completely safe for use by researchers and clinicians for a variety of applications. Many have also been designed and FDA certified for use on patients undergoing surgery. Digitimer amplifiers are low mains noise solutions for accurate recordings of signals such as EMG/EEG.

 

High output, low mains noise, and human safety are Digitimer hallmarks.

DS8R.jpg

DS8R

  • Biphasic Constant Current Stimulator (adjust interphase stimulation and duration)

  • 0 – 1Amp current range with 400V compliance

  • 50-2000 micro second pulse duration

  • Includes remote control software

  • Includes API for programming custom stimulation protocols

  • Includes high frequency “Russian” stimulation capability

ds7a DNA.jpg

DS7A

  • High voltage Constant Current stimulator

  • Digitimer’s “workhorse” stimulator

  • 0 – 100mA

  • 0, 100, 200, 500, 1000, and 2000 microsecond pulse durations

  • On-board trigger or external TTL input trigger control

  • Bipolar

  • FDA cleared

DS7AH DNA.jpg

DS7AH

  • High voltage Constant Current stimulator

  • Digitimer’s “big brother” to the DS7A

  • 0 – 1Amp

  • 0, 100, and 200 microsecond pulse durations

  • On-board trigger or external TTL input trigger control

  • Bipolar

  • FDA cleared

DS7R DNA.jpg

DS7R

  • High voltage Constant Current stimulator

  • Combines high output of DS7AH with pulse duration choices of DS7A

  • 0 – 1Amp

  • 0, 100, 200, 500, 1000, and 2000 microsecond pulse durations

  • Bipolar

  • On-board trigger or external TTL input trigger control

  • Research Applications Only

DS5-Isolated-Bipolar-Constant-Current-Stimulator.jpg

DS5

  • Bipolar constant current stimulator

  • Excellent for nerve excitability studies

  • Turns arbitrary analog voltage waveforms into constant current stimuli.

  • Output ranges of +/- 10, +/- 25, +/- 50 mA for a full scale input

  • Input ranges of +/- 1, +/- 2.5, +/- 5, +/- 10 V full scale

  • Perfect stimulator for the QtracW Threshold Tracking Software for Nerve/Muscle/Cortical excitability studies (contact us for more information)

DG2A 3 NEW.jpg

DG2A

  • Stand alone trigger generator with multiple running modes

  • Battery powered

  • Great solution when more than single stimulus is desired

  • Works with all Digitimer stimulators

D188.jpg

D188

  • Remote electrode selector

  • Hook up to 8 electrode sites to one stimulator

  • Control stimulation with virtual software panel or DAQ

D440 DNA.jpg

D440

  • Two or Four channel amplifier

  • Isolated low noise solution for human EMG/EEG studies

  • Virtual front panel software to adjust gain, filter, and mode settings

  • AC or DC operating modes

D360 DNA.tif

D360

  • 8 Channel patient isolated amplifier

  • Computer controlled

  • Excellent for multi-channel EEG or EMG recording amplification

  • Range of low-cut and high cut band pass filter settings

  • Overall gain of x100 to x2,000,000 

  • Built in impedance checking

BIG d360R-4_edited.jpg

D360R-4

  • 4 channel research alternative to the D360

  • Overall gain of x100 to x3,000,000

  • Windows based software control

D185.jpg

D185

  • MultiPulse Cortical Stimulator

  • Intraoperative Monitoring (IOM) of the spinal cord

  • FDA cleared

  • In use worldwide in leading medical centers

  • 1,000 maximum voltage output

  • 1.5 Amp maximum current output

  • Interfaces with other IOM equipment

  • 50 microsecond pulse duration

bottom of page